Synthes pelvic inventory

Written by Aavwyo NicyicyLast edited on 2024-07-10
• DePuy Synthes recommends predrilling in dense bone when using 5 mm or 6 mm screws. Drill speed.

Fig 1: Acetabular plate in the small, extended version shown on a bone model with fracture pattern (black) and screw trajectories (gray). Due to demographics and an increasingly aging population, pelvic fractures are becoming highly relevant for society and the healthcare system. Moreover, with a shift from nonoperative to operative treatment ...1 DePuy Synthes Companies | EXPEDIUM VERSE System | System Guide. VERSE Unitized Set Screw One-step locking of the polyaxial head ... of sizes providing surgeons thoracolumbar and pelvic fixation options for adolescent and adult pathologies. Available EXPEDIUM VERSE Screw Sizes Diameter Lengths 4.35mm 20-65mm 5mm 20-65mm …The Acumed Pelvic Plating System is a comprehensive set of plates, screws, and instrumentation designed for fractures, fusions, and osteotomies of the acetabulum, sacrum, ilium, and pelvic ring. The Pelvic Plating System can also be used for sacroiliac joint dislocations and pubic symphysis disruptions. The implants in the Pelvic Plating System ...Inventory Control Form Variable Angle Locking Hand System 316L Stainless Steel 2.0 mm Variable Angle Locking Plates 02.130.350 Straight Plate, 6 holes 02.130.351 Straight Plate,12 holes 02.130.352 T-Plate, 3 holes head, 7 holes shaft 02.130.353 Y-Plate, 3 holes head, 7 holes shaft 02.130.354 Phalangeal Base Plate, 2 holes head, 6 holes shaftIMAST 2024 Meeting attendees can visit DePuy Synthes at Booth #10 or learn more online here. For more information about the DePuy Synthes vision to Keep People Moving and the company's unwavering commitment to addressing the most complex and challenging procedures in orthopaedic and neurological spine surgery, read more here. ABOUT DEPUY SYNTHESPRODUCT CODES. DESCRIPTION. The Orthopaedic Cable System is a cerclage system designed for use with the Cerclage Positioning Pins and Hex Buttons in general orthopaedic trauma surgery, prophylactic banding during total joint procedures, and temporary reduction during open reduction procedures. Product Specifications. How to Use This Device.Collinear Reduction Clamp Surgical Technique DePuy Synthes 7 Collinear Reduction Clamp Set (105.907) Graphic Case 60.100.025 Graphic Case for Collinear Reduction Clamp Instruments 314.291 Sliding Mechanism 319.24 2.9 mm Cleaning Brush 398.71 Spiked Disk 398.752 Hohmann-Style Arm, 183 mm 398.753 Pelvic Arm, 225 mm 398.754 Percutaneous Arm, 255 mmProduct Codes: 02.118.002, 02.118.002S, 02.118.003... View More. PRODUCT CODES. DESCRIPTION. The 2.7 mm/3.5 mm VA LCP™ Ankle Trauma System is a comprehensive plating system that merges variable angle locking screw technology with conventional plating techniques for fixation of the ankle when growth plates have fused. Product Specifications.The Acutrak 2 - 7.5 is available in sizes from 40 mm to 120 mm and is inserted using a 4.0 mm hex driver over a .094" guide wire. The Acutrak 2 - 5.5 is part of the latest evolution in fully-threaded headless screw fixation. With instrumentation designed to simplify the surgical technique, the Acutrak 2 - 5.5 is composed of 8 unique screw size ...The LCP (Locking Compression Plate) system offers the surgeon the choice, preoperatively and intraoperatively, of using either standard screws or locking screws - or a combination of the two screw types - for fracture fixation. Experience in the use of LC-DCP or DCP plates or instruction by. a surgeon with experience of their use is ...by the AO and DePuy Synthes and belong still to sur - geons basic armatorium used for fracture treatment, revision surgery and correction osteotomies. Due to their fixed-angle shape, successful application needs planning, concise orientation in all planes (AP and lateral views, rotation) and preparation of the channel for the blade. IntroductionInventory Control Form Modular Hand Structure Implants and Instruments (Stainless Steel) Synthes (USA) To Order: (800) 5230322 Patient Information: Synthes (Canada) Gmbh. To Order: (800) 6681119 Date:. The command console incorporates two hand governors with ... Uses a different form of isomorphic control modeling technology, which enables.DePuy Synthes Low Profile Pelvic System. Improved Implant Fit to Patient Anatomy *1,3,5 The Intrapelvic Acetabular System is designed to provide improved implant fit to the patient anatomy, providing four different plate options to choose from and a range of instruments to contour the plate. Streamlined Surgical Procedure*16 DePuy Synthes Vet Double/Triple Pelvic Osteotomy Plates Surgical Technique The DePuy Synthes Vet DPO/TPO plate is intended for treatment of coxofemoral joint instability and subluxation in immature dogs prior to onset of osteoarthritis. Note: Avoid use in patients with preexisting conditions which could compromise the strength ofOur Trauma & Extremities portfolio offers comprehensive solutions for the treatment of fractures, deformities, and other orthopaedic traumas. Our wide range of surgical instruments and fixation products are designed to provide solutions tailored to the diverse needs of orthopaedic professionals and patients. Get In Touch With a Sales Consultant.Permits rapid reduction and stabilization of the posterior pelvic ring. Description The Pelvic C-Clamp is an emergency stablization instrument for unstable injuries and fractures of the pelvic ring. Unstable pelvic ring fractures can be associated with massive blood loss that can cause terminal shock. The Pelvic C-Clamp allows rapid reduction ...Find your exact synthes low profile pelvic inventory for free on the web! Try our advanced editing features to customize your form. Edit existing text and fill in PDF templates with ease!3.5 mm Low Profile Pelvic System; 4.5 mm Variable Angle LCP ® Curved Condylar Plate; Continuous Compression Implants for Trauma Applications; The Orthopaedic Cable System; Pelvic C-Clamp II; RIA 2 System (Reamer Irrigator Aspirator) TomoFix ® Medial High Tibia Plate; VA LCP™ Periprosthetic Proximal Femur Plating System; Knee. Knee …The EXPEDIUM Growing Spine System features the Extended Tandem Connectors that allow incremental construct lengthening to accommodate the growing pediatric spine. The Extended Tandem Connectors are compatible with both the EXPEDIUM 4.5 Spine System (when using a 4.5 to 5.5 mm transition rod) and the EXPEDIUM 5.5 Spine System.Synthes Surgical Pelvic Reduction Forceps 398.88 $ 375.00. REF # 398.88. IN GOOD CONDITION!! Out of stock. SKU: W3613 Categories: Orthopedic, Synthes. ... Synthes Surgical Self Centering Holding Forceps 398.82 Synthes Surgical 193mm Holding Sleeve 389.814. Cart. Search for: Product categories. Category (12486)Variable Angle Locking Patella Plating System. The VA Locking Anterior Patella Plate 2.7 is designed to address different fracture patterns as per approved indication. The surgical technique guide includes two sections: Complex Fractures - 3-hole and 6-hole plates are recommended. Simple Fractures - Core, 3-hole, and 6-hole plates may be ...In any business, effective inventory management is crucial for success. It involves the process of overseeing and controlling the flow of goods from the moment they are acquired to...DePuy Synthes implants with the implants from other companies is not recommended. The overall performance may be compromised due to differences in design, chemical composition, mechanical properties, and quality. Given these qualities are trade-secret, no competitor of DePuy Synthes can make a genuine claim “the same as DePuy Synthes.”INVENTORY CONTROL 1.7mm Orthognathic LEIBINGER Universal Fixation System (PLATES NOT ACTUAL SIZE) 1.7MM ORTHOGNATHIC SYSTEM INLAY (Order Qty: Pkg of 1) Product No. Description Qty Par Level 1.7mm Standard L Plates, Gold 55-06760 2mm Bar, 100° Left, 5 Hole 55-06761 2mm Bar, 100° Right, 5 Hole 55-06762 5mm Bar, 100° Left, 5 Hole2. Create a blueprint of the proximal femur on the ap pelvic x-ray, rotate this blueprint around the center of the femoral head until you have a satisfactory containment. Calculation of the correction: The angle between the anatomical axis of the femur in the ap x-ray and the adduc-tion x-ray or the ap x-ray and the blueprint, respectively02.108.300, 02.108.300S, 02.108.301... View More. PRODUCT CODES. DESCRIPTION. The Pediatric LCP ™ Plate System is designed for stable fixation of varus, valgus or rotational osteotomies and trauma applications in pediatric orthopaedics. The plates feature a universal design to fit both the left and right femurs. Product Specifications.DePuy Synthes Low Profile Pelvic System. Improved Implant Fit to Patient Anatomy *1,3,5 The Intrapelvic Acetabular System is designed to provide improved implant fit to the patient anatomy, providing four different plate options to choose from and a range of instruments to contour the plate. Streamlined Surgical Procedure*1of DePuy Synthes products. Instruction by a surgeon experienced in handling these products is highly recommended. Processing, Reprocessing, Care and Maintenance For general guidelines, function control and dismantling of multi-part instruments, as well as processing guidelines for implants, please contactVariable Angle Locking Patella Plating System. The VA Locking Anterior Patella Plate 2.7 is designed to address different fracture patterns as per approved indication. The surgical technique guide includes two sections: Complex Fractures - 3-hole and 6-hole plates are recommended. Simple Fractures - Core, 3-hole, and 6-hole plates may be ...The DePuy Synthes Cannulated Compression Headless Screws are indicated for use in bone reconstruction, osteotomy, arthrodesis, joint fusion, fracture repair, and fracture fixation of bones appropriate for the size of the device. Screws are intended for single use only. Contraindications The implant should not be used in a patient who hasMatrixNEURO™ System. The MatrixNEURO™ System features regular (0.5 mm profile) and Ultra Low Profile (0.4 mm profile) implants. In addition, a variety of mesh options are available including various shapes and sizes, as well as contourable, reconstruction, and pre-formed. 1-3. Get In Touch with a Sales Consultant.The Variable Angle LCP™ Curved Condylar Plate is a distal femur implant designed to address multiple patient anatomies, fracture patterns and surgical situations including supracondylar, intra-articular and extra-articular condylar fractures, and periprosthetic fractures. Product Specifications. How to Use This Product.Handy tips for filling out Synthes pelvic inventory online. Printing and scanning is no longer the best way to manage documents. Go digital and save time with airSlate SignNow, the best solution for electronic signatures.Use its powerful functionality with a simple-to-use intuitive interface to fill out Synthes ex fix inventory online, e-sign them, and quickly …SYNTHES (USA) SYNTHES (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J2210-I 10/12 Inventory Control Form 2.4 mm, 3.0 mm, 3.5 mm and 4.0 mm Cannulated Screws 2.4 mm Cannulated Screws Long Thread LENGTH LENGTH 211.810 10 mm 211.811 11 mm 211.812 12 mm 211.813 13 ...The Locking Compression Plate (LCP™ System) System utilizes locking screws to provide the ability to create a fixed-angle construct when traditional screw purchase is compromised. This locking compression technology does not rely on plate-to-bone compression to maintain stability, but functions similarly to multiple small-angled blade plates ...Consult Depuy Synthes's entire Pelvic C-Clamp catalogue on MedicalExpo. Page: 1/20Inventory Control Form TN-ADVANCED™ Tibial Nailing System Implants Date: Hospital: Surgeon: Procedure: Case Information (eg, Case ID): TN-ADVANCED™ Tibial Nailing System Ø 8 mm, Sterile Right Part # Length (mm) 04.043.005S 255 mm 04.043.010S 270 mm 04.043.015S 285 mm 04.043.020S 300 mm 04.043.025S 315 mm 04.043.030S 330 …DESCRIPTION. Our LCP™ Curved Locking Compression Plates are part of the DePuy Synthes Trauma LCP™ Locking Compression Plate System. This stainless steel and titanium plate screw system merges locking screw technology with conventional plating techniques for use in various orthopaedic trauma applications. Get in Touch with a Sales Consultant.The ACTIS™ Total Hip System is the first DePuy Synthes stem specifically designed to be utilized with tissue sparing approaches, such as the anterior approach, as well as traditional approaches. The implant and instrumentation are designed to balance ease-of-insertion and may provide improved implant stability.1Veterinary Inventory Controller Contact Large Fragment Screws, Drill Piece, Taps Synthes (USA) To Order: (800) 523-0322 Date: Synthes (Canada) Ltd. To Order: (800) 668-1119 Hospitalization: Account # Implants 4.5. Synthes Low Profile Pelvic Inventory.01.100.013 Low Profile 3.5 Pelvic Instrument Set 181.600 Basic Pelvic Instrument Set 182.415 LCP Compact Small Fragment Instrument Set 182.456 Instrument Set LC-DCP Precautions: • Instruments and screws may have sharp edges or moving joints that may pinch or tear user's glove or skin. • Handle devices with care and dispose worn boneSurgical Technique d) Firmly attach the self-tapping 3.5 mm screw to the screwdriver and insert it into the protection sleeve. 24 Surgical Technique • Intrapelvic Acetabular System 3.5 mm. f) Using the screwdriver as counterpressure, pull back the protection sleeve until the head of the screw is visible.4 Synthes LCP Proximal Femoral Plate 4.5/5.0 Technique Guide Anatomic reduction Anatomic plate profile assists reduction of metaphysis to diaphysis and facilitates restoration of the neck-shaft angle by proper screw placement. Stable fixation The combination of conventional and locking plate fixation offers optimum fixation irrespective of bone ...Inventory Control Form 3.5 mm Low Profile Pelvic System Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale Canada. Please contact your sales consultant items approved for sale in 3.5LPPELVICICF001v2 …The prognosis for pelvic cancer, depending on its stage at diagnosis, has a five-year survival rate between 93 and 15 percent, according to Cancer.org.Additionally, with our services, all of the info you contain in your Synthes Modular Hand Inventory Control Form the well-protected against leakage or damage through cutting-edge encryption. A system manufactured of an extensive range of basis and specialty plates for fracture repair and deformity correction designed for lateral and dorsal ...External Fixator Devices include pins, wires, rods and clamps to form a frame for the reposition and fixation of bone fragments. Pins and wires are single-use im-plants and build the connection of the frame to the bone(s). Rods and clamps are the parts of the frame that are located outside of the body and are designed for multiple usages.To order (Canada): 844-243-4321. Available nonsterile or sterile-packed. Add "S" to catalog number to order sterile product. Titanium Patella Plates. Implants. Inventory Control Form. 2.7 mm VA Locking Patella Plating System. Stainless Steel (316L) Patella Plates 2.7 mm Variable Angle Locking Screws, Non-Sterile, (10-60 mm), Stainless Steel.How to fill out and drawing Synthes pelvic implant set inventory control print online? Get your back template plus fill it in using progression features. Enjoy smart fillable input and interactivity. Follow the simple instructions below: These converters, turn one handheld are provision a more flexible speed power ...Clinical Resources. Animation Ischial Screw Insertion. Instructions for Use. Intrapelvic Acetabular Plating System Brochure. Intrapelvic Acetabular Plating System Value Analysis Brief (VAB) Inventory Control Form. Surgical Technique Guide. Select all documents (3) Download Selected Items.Dr. Rahul Vaidya is a paid consultant by Smith and Nephew and Johnson and Johnson/Synthes USA to develop an FDA approved device for the INFIX. The implants depicted are off the shelf implants used in the INFIX method. ... The INFIX procedure for anterior pelvic fixation is based on standard techniques that are familiar to the Orthopaedic Pelvic ...Fig 1: Acetabular plate in the small, extended version shown on a bone model with fracture pattern (black) and screw trajectories (gray). Due to demographics and an increasingly aging population, pelvic fractures are becoming highly relevant for society and the healthcare system. Moreover, with a shift from nonoperative to operative treatment ...Description. The Pelvic C-Clamp is an emergency stablization instrument for unstable injuries and fractures of the pelvic ring. Unstable pelvic ring fractures can be associated with massive blood loss that can cause terminal shock. The Pelvic C-Clamp al-lows rapid reduc tion and stabilization of these unstable pelvic ring fractures.Synthes products supplied in a non-sterile condition must be cleaned and steam-sterilized prior to surgical use. Prior to cleaning, remove all original packag - ing. Prior to steam-sterilization, place the product in an approved wrap or contain - er. Follow the cleaning and sterilization instruction given by the Synthes “Import-ant ...3.5 mm LCP Medial Distal Tibia Plates Plate features - natomically contoured; plate is twisted A 20° and bent to fit the distal tibia - vailable for left and right tibias A - imited-contact shaft design with L 4 to 14 combination locking/ compression holes - ight distal locking holes accept E 2.7 mm cortex, 3.5 mm locking, 3.5 mm ...IMAST 2024 Meeting attendees can visit DePuy Synthes at Booth #10 or learn more online here. For more information about the DePuy Synthes vision to Keep People Moving and the company's unwavering commitment to addressing the most complex and challenging procedures in orthopaedic and neurological spine surgery, read more here. ABOUT DEPUY SYNTHESThe DePuy Synthes Dynamic Hip System (DHS) offers treatment options depending on the fracture site and the . ptieant Fixation elements DHS Screw • Stainel ss steel / TAi 6l Nb7 (TAN) • Length 50-145 mm • Outer diameter 13 mm • Coupling: two notches or octagonal DHS Blade • Stainel ss steel /TAN • Length 65-145 mmRestaurant inventory management software is a vital part of a restaurant’s cost control system. See our expert rankings of the best tools. Retail | Buyer's Guide Updated May 9, 202...Synthes products supplied in a non-sterile condition must be cleaned and steam-sterilized prior to surgical use. Prior to cleaning, remove all original packag - ing. Prior to steam-sterilization, place the product in an approved wrap or contain - er. Follow the cleaning and sterilization instruction given by the Synthes “Import-ant ...Variable Angle Locking Patella Plating System. The VA Locking Anterior Patella Plate 2.7 is designed to address different fracture patterns as per approved indication. The surgical technique guide includes two sections: Complex Fractures – 3-hole and 6-hole plates are recommended. Simple Fractures – Core, 3-hole, and 6-hole plates may be ...6 DePuy Synthes 6.5 mm and 7.3 mm Cannulated Screws Surgical Technique. Option 1a: Insert additional parallel guide wire(s) with adjustable parallel wire guide Use the 2.8 mm adjustable parallel wire guide to place parallel wires at various distances from the fi rst wire. Place the fi xed sleeve over the pre viously inserted wire and adjust the movable sleeve …Pins, and Pelvic C-Clamp Cannulated Nails. Schanz Screws and Steinmann Pins can be used in various anatomical locations in the body based on the external fixation and distraction system being utilized. The Pelvic C-Clamp Cannulated Nails are only used in the pelvic ring. All external fixator implants are single packed. Schanz screws and ...Permits rapid reduction and stabilization of the posterior pelvic ring. Description The Pelvic C-Clamp is an emergency stablization instrument for unstable injuries and fractures of the pelvic ring. Unstable pelvic ring fractures can be associated with massive blood loss that can cause terminal shock. The Pelvic C-Clamp allows rapid reduction ...3.5 mm LCP Medial Distal Tibia Plates Plate features – natomically contoured; plate is twisted A 20° and bent to fit the distal tibia – vailable for left and right tibias A – imited-contact shaft design with L 4 to 14 combination locking/ compression holes – ight distal locking holes accept E 2.7 mm cortex, 3.5 mm locking, 3.5 mm ...The Titanium Sternal Fixation System provides internal fixation of the sternum for primary or secondary closure and repair. 1,2. Get in Touch with a Sales Consultant.This site is published by the DePuy Synthes Companies, which are solely responsible for its content. This site is intended for use by residents of Latin America, Europe, Middle East and Africa, Asia & Pacific only.How to fill out and drawing Synthes pelvic implant set inventory control print online? Get your back template plus fill it in using progression features. Enjoy smart fillable input and interactivity. Follow the simple instructions below: These converters, turn one handheld are provision a more flexible speed power ...TN-ADVANCED™ Tibial Nailing System. Product Codes: 03.043.002, 03.043.003, 03.043.004... View More. PRODUCT CODES. DESCRIPTION. The TN-ADVANCED™ Tibial Nailing System (TNA) is an intramedullary nailing system for tibia fractures. This fixation system features design improvements to address previously unmet challenges with intramedullary ...Our DePuy Synthes Hammertoe Continuous Compression Implants provide fixation for hammertoe correction procedures. This system features all contents in one sterile packed kit: Pre-loaded Nitinol implant in Standard or Large size options. Insertion tool with easy-to-use slider tab. Drill Guide, pins, and k-wire. Get in Touch with a Sales Consultant.Synthes 9. Open the catalog to page 11. 0x6.001.024_AA 13.10.09 10:05 Seite 10 Implantation 5 Position and align plate Instruments 03.113.009 Outer Sleeve for …Preservation of blood supply. Preservation of the blood supply to soft tissues and bone by gentle reduction techniques and careful handling. have become the guidelines for internal fixation.1,2. Anatomic reduction. Fracture reduction and fixation to restore anatomical relationships. Early, active mobilization.synthes pelvic inventory control form; small frag inventory sheet; If you believe that this page should be taken down, please follow our DMCA take down processhere. Ensure the security of your data and transactions. USLegal fulfills industry-leading security and compliance standards. VeriSign secured #1 Internet-trusted security seal. ...2.Create a template of the proximal femur on the AP pelvic x-ray, rotate this template around the center of the femoral head until you have a satisfactory containment. x Assess the correction that will achieve coverage (3) x Choose a target neck/shaft angle based on patient pathology (4) Calculate the correction angle: The angle betweenThe Pelvic C-Clamp II is an emergency stabilization instrument that provides quick and efficient compression and stabilization of pelvic fractures in the emergency room, on the x-ray table, and in the operating room. It also works to control hemorrhaging in the unstable posterior pelvic ring. 1. Product Specifications.9. DePuy Synthes Validation Lab Questionnaire Results for Femoral Recon Nail System. 12/06/2017. Windchill Document #0000266807. 10. DePuy Synthes Shared Instrumentation TFNA-FRN A.7. 2/8/2018. Windchill Document #0000273347. 11. DePuy Synthes Design Verification Report - T115 FRNProtection Tube - Bending Resistance. 10/13/2017.Orthopaedic Foot Instruments Surgical Technique DePuy Synthes 1 MR Information The Orthopaedic Foot Instruments have not been evaluated for safety and compatibility in the MR environment. It has not been tested for heating, migration or image artifact in the MR environment. The safety of the Orthopaedic FootIf you have a specific Medical Information Request, please use this Medical Information Request form instead of this form, so that your request can be correctly managed directly by our Medical Affairs team. The personal data collected on this form, will be used to validate your request & also manage our relationship with you.Inventory Control Form TomoFix® osteotomy System Patient Information: 5.0 mm Titanium Locking Head Screws, self-tapping lenGtH 413.324 24 mm 413.326 26 mm 413.328 28 mm 413.330 30 mm 413.332 32 mm 413.334 34 mm 413.336 36 mm 413.338 38 mm 413.340 40 mm 413.342 42 mm 413.344 44 mm lenGtH 413.346 46 mm 413.348 48 mm 413.350 50 mm 413.355 55 mmPosition the image intensifier as for an AP view of the proximal femur. Using long forceps, hold the ruler paral-lel to the femur on the lateral side of the upper leg. Position the ruler such that the end is located at or just below the level of the tip of the greater trochanter. Mark the skin on the lateral side.Synthes USA, LLC 1101 Synthes Avenue Monument, CO 80132 Manufactured or distributed by: Synthes USA Products, LLC 1302 Wrights Lane East West Chester, PA 19380 To order (USA): 800-523-0322 To order (Canada): 844-243-4321 Note: For recognized manufacturer, refer to the product label. www.depuysynthes.com Synthes GmbH Luzernstrasse 21 4528 ...Synthes Pelvic Implant Set (125.885) Plates Catalog # Description 224.02 4.5 mm Narrow DCP Plate, 2 Holes, 39 mm Length (2) 229.33 4.5 mm Reconstruction Plate, 3 Holes, 45 mm Length (2) 229.34 4.5 mm Reconstruction Plate, 4 Holes, 61 mm Length (3) 245.00 3.5 mm Reconstruction Plate, 10 Holes, 118 mm Length (2)6 DePuy Synthes Large Distractor–Femur Surgical Technique Universal Joint Assembly 1 Select a 14.0 mm threaded spindle (A) of appropriate length (most likely 480 mm). A transverse hole will be in the proximal end when applied to the femur. 2 Turn the end piece with double joint (B) onto the threadedThe number of homes available for sale is finally improving, providing some hope for buyers burned out by an extremely competitive market. By clicking "TRY IT", I agree to receive ...Inventory Control Form Zero-P Patient Information: Synthes (USA) To Ordering: (996) 592-1154 Synthes (Canada) Ltd. To Your: (355) 431-4088 Date: Hospital: Surgeon: Procedure: Implants 5.8 mm Titanium. Implants cont'd Inventory Manage Form 6 Available nonsterile or.The Pelvic C-Clamp II is an emergency stabilization instrument that provides quick and efficient compression and stabilization of pelvic fractures in the emergency room, on the x-ray table, and in the operating room. It also works to control hemorrhaging in the unstable posterior pelvic ring. 1. Product Specifications. About This Product. The LCP™ Proximal Tibia Plates are indicated for fractures of the proximal tibia and treat

Edit synthes low profile pelvic inventory form. Rearrange and rotate pages, insert new and alter existing texts, add new objects, and take advantage of other helpful tools. Click Done to apply changes and return to your Dashboard. Go to the Documents tab to access merging, splitting, locking, or unlocking functions.Now, working with ampere Synthes Inventory Controlling Download requires a maximum of 5 minutes. Our state web-based voids the obvious guidelines eliminate human-prone errors. Treatment guidelines leads to individual leitung also potential. Adhere to our comfortable steps to receive your Synthes General Command Form well prepared quickly:This site is published by the DePuy Synthes Companies, which are solely responsible for its content. This site is intended for use by residents of Latin America, Europe, Middle East and Africa, Asia & Pacific only.4 Synthes Large and Medium-Size External Fixators Surgical technique The modular construction of Large and Medium-size External Fixators makes them highly flexible. A variety of proven forms of assembly can be used to externally stabilize long, tubular bones and pelvic ring fractures as well as arthrodesis and osteotomies.Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Patient Information: Inventory Control Form 2.7 mm / 3.5 mm Variable Angle LCP Elbow System 02.107.002 2 holes, right 02.107.102 2 holes, left 2.7 mm / 3.5 mm Variable Angle LCP Proximal Olecranon Plates 02.107.202 2 holes ...Execute Synthes Low Profile Pelvic Inventory in just a couple of clicks by following the instructions listed below: Pick the document template you will need in the collection of legal forms. Choose the Get form button to open the document and begin editing. Submit the necessary fields (they are marked in yellow). The Signature Wizard will allow you to put …02.108.300, 02.108.300S, 02.108.301... View More. PRODUCT CODES. DESCRIPTION. The Pediatric LCP ™ Plate System is designed for stable fixation of varus, valgus or rotational osteotomies and trauma applications in pediatric orthopaedics. The plates feature a universal design to fit both the left and right femurs. Product Specifications.The Pelvic Implant and Instrument Sets contains implants, reduction instruments, retractors and instruments for screw and plate fixation for the operative treatment.2 DePuy Synthes Spring Plates 3.5 Surgical Technique Description In­pelvic­and­acetabular­surgery,­it­is­often­difficult­to­reduce­ and­fix­small­bone­fragments.­The­Spring­Plates­3.5­are­in-tended­to­reduce­and­stabilize­bone­fragments­that­are­too­ …DePuy Synthes Medium External Fixator System devices may present issues if the MR imaging area of interest is in or near the area where the fixator frame is located. • For FFE sequence: scan duration 3 minutes, TR 100 ms, TE 15 ms, flip angle 15° and SE sequence: scan duration 4 minutes, TR 500 ms, TE 20 ms, flip angleof the DePuy Synthes Distal Radius Fixator construct, and it may be necessary to optimize MR imaging parameters, to compensate for the presence of the fixation frame. Representative devices used to assemble a typical DePuy Synthes Distal Radius Fixator have been evaluated in the MRI chamber and worst-case artifact information is provided below.3.5 mm Intrapelvic Acetabular System. Michael D Stover, David Stephen, Jorge D Barla, Robin E Peter, Ramesh K Sen. Observed trends in fracture patterns and a shift from non-operative to surgical treatment in pelvic fractures defined a need for new intrapelvic acetabular stabilization devices. Fracture types frequently include associated both ...4 DePuy Synthes 1.5 mm LCP® Modular Mini Fragment System Surgical Technique AO Principles In 1958, the AO formulated four basic principles, which 1 4 2 3 4_Priciples_03.pdf 1 05.07.12 12:08 4 DePuy Synthes Expert Lateral Femoral Nail Surgical Technique AO PRINCIPLES In 1958, the AO formulated four basic principles, whichEdit synthes pelvic inventory form. Text may be added and replaced, new objects can be included, pages can be rearranged, watermarks and page numbers can be added, and so on. When you're done editing, click Done and then go to the Documents tab to combine, divide, lock, or unlock the file.Complete Synthes Modular Hand Inventory Remote Form online with US Legal Print. Easily fill unfashionable PDF blank, modify, and sign them. Save with instantly send your ready documents.Product Codes : 03.010.127, 03.010.048, 04.003.240S... View More. PRODUCT CODES. DESCRIPTION. The EXPERT™ Cannulated Lateral Entry Femoral Recon Nail is designed to facilitate a lateral trochanteric entry site in the greater trochanter, providing ease of access while reducing the chance of varus deformity. Product Specifications.Universal Small Fragment System System Catalog DePuy Synthes 12 Instruments Core System Trays Anatomic Implant Trays Case & Lid Options Set Information Instruments (Continued) SKU Description 03.133.175 2.5 mm Hex Driver Shaft, Self-Retaining Length 100 mm with Quick Coupling 03.133.200 Plate Bending Iron Closed for 2.7/3.5 mm PlatesConsult Depuy Synthes's entire 2.4 mm VA LCP™ catalogue on MedicalExpo. Page: 1/4About This Product. The Hindfoot Arthrodesis Nail permits a proper hindfoot alignment due to features such as: · Distal and talar locking options. · A spiral blade. · Lateral bend · End caps for improved stability2,3. Get in Touch with a Sales Consultant.If you have a specific Medical Information Request, please use the following web form Medical Information Request instead of the below, so that your request can be directly managed by our Medical Affairs team. Contact UK Customer Services (+44 113 387 7800) Order products with J&J Customer Connect. The DePuy Synthes UK customer support team is ...Variable Angle Locking Patella Plating System. The VA Locking Anterior Patella Plate 2.7 is designed to address different fracture patterns as per approved indication. The surgical technique guide includes two sections: Complex Fractures – 3-hole and 6-hole plates are recommended. Simple Fractures – Core, 3-hole, and 6-hole plates may be ...About This Product. The FIBULINK Syndesmosis Repair System provides a repair solution for ankle fractures of the syndesmosis. It is compatible with all DePuy Synthes distal fibula plates and is packaged in sterile, single-use packaging. This system features: Stainless steel or titanium implants. Tibia Screw. PERMACORD™ Suture Bridge. Fibula Link.DESCRIPTION. Our LCP™ Curved Locking Compression Plates are part of the DePuy Synthes Trauma LCP™ Locking Compression Plate System. This stainless steel and titanium plate screw system merges locking screw technology with conventional plating techniques for use in various orthopaedic trauma applications. Get in Touch with a Sales …Inventory Control Form - Stainless Steel. View PDF. Inventory Control Form - Titanium. View PDF. Select all documents (2) Download Selected Items. -. DePuy Synthes 3.5 mm Periarticular Proximal Humerus Plates are indicated for fractures, fracture dislocations, osteotomies, and nonunions of the proximal humerus, particularly in osteopenic bone.External Fixator Devices include pins, wires, rods and clamps to form a frame for the reposition and fixation of bone fragments. Pins and wires are single-use im-plants and build the connection of the frame to the bone(s). Rods and clamps are the parts of the frame that are located outside of the body and are designed for multiple usages.3.5 mm Low Profile Pelvic System. Ouch! Your graphics card does not support WebGL. Find out how to fix it here. Please refer to the instructions for use for a complete list of indications, contraindications, warnings and precautions. visualized by pixelmolkerei.ch. Interactive 3D Web application by pixelmolkerei.Consult Depuy Synthes's entire Pelvic C-Clamp catalogue on MedicalExpo. Page: 1/20Inventory Control Form LCP Clavicle Plate System Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J9001-D 10/10 3.5 mm LCP Superior Anterior Clavicle Plates, with Lateral Extension 3.5 mm LCP Superior Anterior Clavicle Plates HOLES HOLESIn-situ Bending Instrument Set Technique Guide Synthes 1 In-situ bending or correction of the bending radius Instrument 03.100.090 In-situ Bending Pliers Grasp the preliminarily fixated plate with the in-situ bending pliers. The nose and counter-bearing mouth of the pliers must sit in the notches of the reconstruction plate. SqueezeThe Synthes Proximal Femur Plates family of implantable devices consist of LCP™ Proximal Femoral Plate 4.5/5.0 and Synthes LCP™ Proximal Femoral Hook Plate 4.5/5.0 and are available in various sizes in both sterile and non-sterile package configuration. ... 3.5 mm Low Profile Pelvic System;20-65mm features which help surgeons to meet the challenge of complex pathologies. 20-65mm EXPEDIUM VERSE Implants are available in an extensive range 20-65mm of sizes providing surgeons thoracolumbar and pelvic fixation 30-100mm options for adolescent and adult pathologies. Page 11 The EXPEDIUM VERSE SYSTEM is presented in four core …About This Product. The Pelvic C-Clamp is comprised of: Rails (inner and outer) Arms (upper and lower) Buttons (side and upper) Cannulated nails (190 mm or 210 mm) Locking mechanism. Threaded tube. Get in Touch with a Sales Consultant.PRODUCT CODES. DESCRIPTION. The Orthopaedic Cable System is a cerclage system designed for use with the Cerclage Positioning Pins and Hex Buttons in general orthopaedic trauma surgery, prophylactic banding during total joint procedures, and temporary reduction during open reduction procedures. Product Specifications. How to Use This Device.Inventory Control Form Distal Radius Fixator Kirschner Wires with trocar point (10/pkg.) SYNTHES (USA) SYNTHES (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Fixation Material Patient Information: Distal Radius Fixators, sterile J7013-C 9/12 Self-Drilling Schanz Screws (stainless steel)Femoral Neck System. The Femoral Neck System (FNS) is engineered for femoral neck fractures.1. Regardless of construct size, FNS offers enhanced rotational stability. Mechanical testing indicates up to 40% increased rotational stability when comparing to a sliding hip screw (SHS).2,4. Get in Touch with a Sales Consultant.The Angular Stable Locking System (ASLS) provides angular and axial stability for screws used in combination with an intramedullary nail in the fixation of fractures. Provides improved stiffness and decreased interfragmentary movement compared to conventional locking. 1-3. Product Specifications. How to Use This Product.02.108.300, 02.108.300S, 02.108.301... View More. PRODUCT CODES. DESCRIPTION. The Pediatric LCP ™ Plate System is designed for stable fixation of varus, valgus or rotational osteotomies and trauma applications in pediatric orthopaedics. The plates feature a universal design to fit both the left and right femurs. Product Specifications.Mortality. Constantini et al J Trauma Acute Care Surg 2016. - multi-centred prospective study of 1339 patients with pelvic fractures at Level 1 trauma centers. - overall mortality 9%. - pelvic trauma with shock has 30% mortality. Dente et al Am J Surg 2005. - 44 open pelvic fractures. - overall mortality 45%. - concurrent intra-abdominal injury ... Synthes reusable devices, instrument trays and cases, as well as processing of DePuy

Reviews

Synthes 3.0 mm Cannulated Screws, Long Thread With Cruciform Recess 36 mm. Synthes 3.5 mm P...

Read more

The recently introduced implant FNS (DePuy Synthes, Zuchwil, Switzerland) ... Hip Pelvis...

Read more

The DePuy Synthes Variable Angle Locking Hand System consists of plates that are anato...

Read more

The Synthes Large External Fixation System is intended to provide treatment for long bone and pelvic frac...

Read more

The Small External Fixation System provides stable fixation for fractures of the small bones including the D...

Read more

Inventory Control Form J7271-D 9/09 Drill Bits 03.226.003 4.8 mm Cannulated Trapeziu...

Read more

Edit, sign, both share synthes small frag catalog live. No need to install programme, just g...

Read more